 HC9 Series HIGH CURRENT 9 Power Inductors
Description RoHS 2002/95/EC * 155C maximum total temperature operation * Surface mount inductors designed for higher speed switch mode applications requiring lower inductance, low voltage and high current * Design utilizes high temperature powder iron material with a non-organic binder to eliminate thermal aging * Inductance Range from 0.2 uH to 47.0 uH * Current Range from 95.0 Amps to 3.65 Amps * Frequency Range 1kHz to 500kHz Applications * Next generation processors * High current DC-DC converters * VRM, multi-phase buck regulator * PC, Workstations, Routers, Servers Environmental Data * Storage temperature range: -40C to +155C * Operating temperature range: -40C to +155C (range is application specific) * Solder reflow temperature: +260C max for 10 seconds maximum
Part Number HC9-R20-R HC9-R47-R HC9-1R0-R HC9-1R5-R HC9-2R2-R HC9-3R3-R HC9-4R3-R HC9-6R8-R HC9-100-R HC9-220-R HC9-330-R HC9-470-R Rated Inductance H 0.20 0.47 1.0 1.5 2.2 3.3 4.3 6.8 10.0 22.0 33.0 47.0 OCL (1) nominal +/-15% H 0.218 0.544 1.04 1.70 2.53 3.52 4.67 7.45 10.9 22.4 34.5 49.2 Irms (2) Amperes (Typ.) 46.7 33.7 23.7 21.0 17.2 14.3 13.0 10.3 8.50 6.30 4.42 3.65
Packaging * Supplied in tape and reel packaging, 450 parts per reel
Isat (3) Amperes 20% rolloff 65 40 28 22 18 15 13.2 11.4 8.6 6.0 4.8 3.9
Isat (4) Amperes 30% rolloff 95 57 41 32 26 22 19.1 15.1 12.5 8.7 7.0 5.7
DCR (m) max. @ 20C 0.50 0.88 1.87 2.27 3.37 4.87 5.90 9.40 14.0 25.7 48.8 72.3
Volts (5) Sec (VS) 2.87 4.78 6.70 8.46 10.4 12.4 14.4 18.1 22.0 31.5 37.3 44.8
1) Test Parameters: 100KHz, 1.0Vrms 2) Irms Amperes for approximately T of 40C without core loss. De-rating is necessary for AC currents. PCB layout, trace thickness and width, airflow, and proximity of other heat generating components will affect the temperature rise. It is recommended that the temperature of the part not exceed 155C under worst case conditions verified in the end application. 3) Peak current for approximately 20% rolloff @20C 4) Peak current for approximately 30% rolloff @20C 5) Applied Volt-Time product (V-S) across the inductor. This value represents the applied V-S at operating frequency necessary to generate additional core loss which contributes to the 40C temperature rise. De-rating of the Irms is required to prevent excessive temperature rise. The 100% V-uS rating is equivalent to a ripple current Ip-p of 20% of Isat (30% rolloff option).
Part number definition: First 3 characters = Product code and size. Last 3 characters = Inductance in H. R = decimal point. If no R is present third character = # of zeros.
Mechanical Diagrams
Dimensions in Millimeters. All dimensions +/-0.2 mm unless otherwise specified. wwllyy = Date Code, R = Revision Level
HC9 Series HIGH CURRENT 9 Power Inductors
Packaging Information
Dimensions in Millimeters
Rolloff
Core Loss
PM-4125 8/06 (c) Cooper Electronic Technologies 2006
Visit us on the Web at www.cooperbussmann.com 1225 Broken Sound Pkwy. Suite F Boca Raton, FL 33487 Tel: +1-561-998-4100 Toll Free: +1-888-414-2645 Fax: +1-561-241-6640
This bulletin is intended to present product design solutions and technical information that will help the end user with design applications. Cooper Electronic Technologies reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Electronic Technologies also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Life Support Policy: Cooper Electronic Technologies does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.


▲Up To Search▲   

 
Price & Availability of HC9-220-R

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X